VWS Tengely elfordító rendszer
- Individual adjustment of the turning bars to the machine environment
- Control components and complete systems with turning bar available
- Optional turning bar with pneumatic ventilation
TECHNICAL SPECIFICATIONS
Operating voltage, nominal value | 24 V DC |
Operating voltage, nominal range | 20 to 30 V DC |
Operating voltage nominal range with power supply | 115 to 460 V, 50/60 Hz |
Current consumption actuating drive AG 2491 | 1.6 A DC |
Current consumption actuating drive AG 2591 | 3.6 A DC |
Current consumption actuating drive AG 2691 | 5.6 A DC |
Nominal width NW | 400 to 3000 mm |
Turning bar diameter | 80/100/120/160/200 mm |
Nominal actuating travel | Max. ±25/50/75/100 mm |
Actuating speed | 25 mm/s |
Web tension | Max. 2000 N |
Positional accuracy | < ±1 mm (material-dependent) |
Error frequency | Max. 0.5 Hz |
Ambient temperature | +10 °C to +50 °C |
Protection class | IP 54 |
Measuring range, infrared edge sensor FR 52 | ±10 mm |
Measuring range, ultrasonic edge sensor FX 52 (FX 42) | ±10 mm / ±3 mm |