Positional accuracy FR 46/FX 46/FE 52 |
< ±0,1 mm (material-dependent) |
Positional accuracy FR 61 |
< ±0,2 mm (material-dependent) |
Error frequency |
Max. 8 Hz |
Nominal actuating travel TL 180 mm/200 mm |
Max. ±19 mm / Max. ±21 mm |
Nominal actuating travel TL 250 mm/300 mm |
Max. ±14,5 mm / Max. ±18 mm |
Nominal actuating speed at outfeed roller |
1 to 170 mm / s |
Web tension NW 160/200/250/300/350 mm |
max. 300 N |
Web tension NW 400/450 mm |
max. 200 N |
Roller diameter D |
40/60/80 mm |
Ambient temperature |
+10 °C to +50 °C |
Relative humidity |
15 to 95 % (non-condensing) |
Operating voltage, nominal value |
24 V DC |
Nominal range |
20 to 30 V DC (ripple included) |
Nominal range with power supply |
100 to 240 V, 50/60 Hz |
Current consumption |
max. 4.5 A DC |
Interface |
Ethernet ELNET Protocol |
Fieldbus interface, optional |
Ethernet UDP |
Ethernet IP |
Profinet |
Digital I/O interface |
5 digital inputs, configurable |
1 output, configurable |
Certification |
CE-compliant (machine directive |
2006/42/EG) |
NRTL certificate CU72180310 01 |
Protection class |
IP 54 |